- MDR-4 identifying
- LR2W support
- Bind LDE menu removed
- Auto LDE calibrate on MDR calibrate
- Minor bug fixes
- "MDR, SD" recording mode added
- "Virtual Production" mode added
- Support for Cooke /i Lens as data source
- Modified "Status display"
- Tilt/roll
- Dual file output (.csv and .dcs)
- New DCS protocol
- DCS protocol conforms to Prot. Descr. 0.9.2
- .dcs file id changed to "DCS2.0 BINARY DATA\n"
- LDT-R2 code runs on LDT-F1 PCB1.0
- LDT-V1 and LDT-VM added (DCS protocol on Ethernet)
- Ethernet and Motion sensor test added to LDT test
- "Aux data output" menu changed to "CAM Port"
- "SERIAL Port" menu added
- Optional DCS protocol on "Serial" port
- DCS "POSITION DATA" message relaying from Serial to DCS output stream
- Freerunning DCS sending added (30 fps if there’s no TC in)
- "Pull from LDT-A2" added (experimental, more tests needed)
- Modified network settings (netmask, router, multicast added)
- Internal data flow enhancements
- LDT-VM bug fixes
- New encoder driver supporting both LDT-E1 and LDT-E2
- Modified encoder calibration algorithm
- Modified "Motor Status" display
- Updated Remote LDT protocol (1.11 does not work)
- Simplified Network Setup menu
- "Komodo, SD" MODE added
- Modified FIZ display (Blinking "CAM" or "MDR" may appear)
- Modified FIZ display ("TC Int" icon instead of the 2 row "INT TC" text)
- RAW encoder data added to DCS stream
- "Save Config" added to Main menu
- "Load Config" added to Settings menu
- "DCS Protocol" added to Settings->Advanced
- Komodo connect bugfix
- DCS protocol "Zeiss Zd Data" really conforms to Prot. descr. 0.9.2
- RED Element Technika sends 0.1 for unknown values once per second
- Data source -> "Pull from cmotion" added (cmotion is unreliable)
- "Create new clip folder" menu added to Main menu
- "Clipfile status" display added
- Data source -> "Pull from LCUBE" added (AMO-1 cable)
- "Motor direction" changed to "Motor/LDE setup"
- "Set AUX to" added to Motor/LDE setup menu
- DCS stream contains Zeiss Distortion data if available
- Data source -> "Pull from cmotion" changed to "Pull from Camin"
- Data source -> "Pull from DXL cmtn" added
- RCP2 Metadata implemented
- "brand" changed to "Lens Owner" in Add lens menu
- "brand" restored.. (see 1.21)
- LDT-E2 bug workaround
- Network PPP driver bugfix
- RED RCP2 Lens owner/brand/serial sending (still experimental)
- RED RCP2 Zoom value bugfix (x10)
- First official LDT-F1 release
- First LDT-V2 release
- Cooke/i lens Fujinon T2.9 workaround
- LDT-F1 "Overlay opacity" menu added
- LDE maximum span increased to 25 encoder turns
- Panavision XL2 support added to LDT-F1
- Fixes an issue where some LDT-R2s were failing the LDT-Tester.
- ARRI MiniLF support (static IP needed: 192.168.0.100)
- Selectable file format (dual mode no longer available)
- Enhanced frame data buffering
- LDT-V2 radio freq setting added (2200 ... 2400 MHz in 10 MHz steps)
- Config load minor bugfix
- LDT-V2 freq setting bugfix
- "MiniLF SD" mode cannot be selected on LDT-R2 (bugfix)
- Venice Tally no longer supported
- Ethernet based "Venice SD" mode added. File name and start/stop. Required camera settings:
Technical->Network->Setting = LAN
Technical->Network->LAN->DHCP = Off
Technical->Network->LAN->IP Address = 192.168.2.50
Technical->Network->LAN->Subnet mask = 255.255.255.0
Technical->Authentication->User name = admin
Technical->Authentication->Password = ABCD1234
- V2 transmitter frequency can be set in 1 MHz steps (2200-2500)
- LDE calibration minimum span decreased to 1/8th round (1000 encoder steps)
- Modified Motor/LDE setup menu
- "AUX set to" changed to MDR motor assign
- All largebody ALEXAs work
- LDT-F1 Anamorph desqueeze
- LDT-F1 Overlay FPGA V2.0 support
- RED RCP2 wide FIZ display bugfix
- External MDR control added to LDT-V2
- "Calibrate" no longer calibrates MDR
- "Calibrate" renamed to "Calibrate LDT-E"
- Lens brand and lens name on "Venice12pin" fixed to "DCS"
- "Factory Defaults" added to Settings->Advanced
- Support for tester initiated "Format card" and "Factory reset""
- MiniLF reconnect in case of JSON parse error
- Unknown lens serial replaced to '-' instead of '???' if auto lens select is on
- User configurable IP addresses for Mini LF and Venice
- Modified lens file name generation for special (-->unusual) cases
- Silently dropping lens files with wrong file names
- Modified lens file name generation for special (-->unusual) cases
- Browse clips function added (limited to 100 clips)
- "DCS Zoom test 11-110 (1)" lens added as internal lens
- Factory default setting of "Auto lens select" set to "off"
- RED RCP2 sends near/far focus, frequency decreased to 20 fps from 25
- Tilta Nucleus-M support added
- initial .xml map conversion draft
- .xml map conversion INF correction
- Big, flashing "NO TC", "NO CAM", "NO MDR" in the FIZ (Main) screen
- Lens serial number can only contain numbers
- New fields in .csv with Alexa:
- Long clipnames
- Tilta Nucleus-M support added
- Unified .csv header lines
- Clipfile INF modifications
- .tab improvements (Unified motor directions, uncompressed focus)
- MDR SW version added to "INFO" menu
- Saving MDR SW version to Setup file
- MiniLF clip name bugfix
- New fields in .csv with MiniLF:
- "Camera FPS"
- "Date"
- "Camera Serial"
- "Camera Type" - Camera Sw. version, eg. MiniLF_7.3.0
- RED RCP2 unavailable near/far values substituted by focus value
- RED RCP2 unavailable iris substituted by f/0.1
- Non-camera generated clip name bugfix (wrong since 1.45)
- "Camera type" in .csv header defaults to "Mode="
- Squeeze Factor added to lens tables (Add lens / Edit lens)
- LDT-F1 changes:
- Put ArriFlex camera types to "Camera type" in .csv header (should be tested!)
- Improved overlay background settings
- Added overlay text brightness
- Individually selectable overlay items
- "Set by lens" mode added to Overlay->Desqueeze menu
- Added Desqueeze on/off to main menu
- Added 1 second to the "Camera ref T/C" header in csv files
- Flip axis data for lens conversion
- "Files converted" message added to "Convert lens files" menu
- LDT-F1: added "FPGA Version" to "Info" menu
In conjunction with FPGA Ver. 3:
- Added 100-200% user zoom
- Added Mirror image (Off, H, V, H+V)
- "Shrink video to fit" moved to zoom menu
- LDT-F1 PAL/NTSC support (works only with FPGA Ver. 3 or newer)
- LDT-F1 ARRICAM->XL2 changeover issue workaround
- Removed flip axis data for lens conversion, reversed motor directions
- "Add lens" bug fixes
- Added "centre mark" to LDT-F1
- CVBS to 1080p upscale modes added to LDT-F1
- Added "Max 16GB SD Card" error message